Glass Colour
- Home
- Glass Colour
What are the benefits of solar control glass?
Solar control
Summer months can be very hot, which means keeping the inside of a building comfortable while allowing natural daylight in can be a challenge. The special properties of solar control glass let natural daylight in, while reflecting a high proportion of the sun’s heat. The indoor space remains bright but cooler compared to uncoated glass.
Thermal insulation
In terms of thermal insulation performance, most of our solar control glass products – those with at least one silver coating, help reflect indoor heat back into the room and form a shield against the cold exterior. Used in double or triple glazing, they help reduce energy costs associated with indoor heating systems.
Energy saving
The energy efficiency of buildings can be improved as solar control glass helps limit the overheating of interiors through the glazing, therefore helping to reduce demands on air conditioning.
Glare reduction
Solar control glass can help mitigate glare from the sun and increase the visual comfort of building occupants, particularly if a glazed façade is directly exposed to the sun and with a high window-to-wall ratio.
Can be folded, Great sun protection High durability, Guaranteed
Bronze color & finish
11% light transmission, 22% from the solar factor
THICKNESS TITLE
3 – 12 mm
APPLICATIONS TITLE Facades
Windows
Doors
Curtain Walls
Roofs
Skylights
OPTIONS TITLE Tempered
Laminated
Heat Soaked
Heat Strengthened
AVAILABLE SIZESMaximum Height x Width: 3210 x 6000 mm
RECOMMENDED COATING POSITIONS Monolithic: 2
Double Glazed: 2
EDGE DELETION Required: NO
APPLICATION TYPE Can be used in: Monolithic or Insulating Glass Unit

TRANSMITTANCE Visible Light 30
Ultraviolet 26
Solar Energy 21
Light to Solar Gain (LSG) 1.04
REFLECTANCE Visible Light Outside 28
Visible Light Inside 19
Solar Energy Outside 18
U-VALUE Summer Daytime – Air [W/m²·K] 1.38
HEAT GAINRelative Heat Gain (RHG) W/m² 215
Solar Heat Gain Coefficient (SHGC) 0.28
COMPOSITION Composition 6 mm / 16 mm / 6 mm – HD Colours coating on surface #2, ClimaGuard Premium 2S coating on surface #3
Glass 1 & Coating Guardian HD Green on Clear
Glass 2 & Coating Premium 2S
Gap 1 100% Air
Calculation Standard NFRC 2010

TRANSMITTANCE Visible
Ultraviolet 33
Solar Energy 32
Light to Solar Gain (LSG) 0.71
REFLECTANCE Visible Light Outside 27
Visible Light Inside 16
Solar Energy Outside 15
U-VALUE Summer Daytime – Air [W/m²·K] 4.8
HEAT GAIN Relative Heat Gain (RHG) W/m² 383
Solar Heat Gain Coefficient (SHGC) 0.47
COMPOSITION Composition 6 mm – coating on surface #2
Glass 1 & Coating Guardian HD Green on Clear
Calculation Standard NFRC 2010
Green color & finish
11% light transmission, 23% from the solar factor
THICKNESS TITLE
3 – 12 mm
APPLICATIONS TITLE Facades
Windows
Doors
Curtain Walls
Roofs
Skylights
OPTIONS TITLE Tempered
Laminated
Heat Soaked
Heat Strengthened
AVAILABLE SIZESMaximum Height x Width: 3210 x 6000 mm
RECOMMENDED COATING POSITIONS Monolithic: 2
Double Glazed: 2
EDGE DELETION Required: NO
APPLICATION TYPE Can be used in: Monolithic or Insulating Glass Unit

TRANSMITTANCE Visible Light 30
Ultraviolet 26
Solar Energy 21
Light to Solar Gain (LSG) 1.04
REFLECTANCE Visible Light Outside 28
Visible Light Inside 19
Solar Energy Outside 18
U-VALUE Summer Daytime – Air [W/m²·K] 1.38
HEAT GAINRelative Heat Gain (RHG) W/m² 215
Solar Heat Gain Coefficient (SHGC) 0.28
COMPOSITION Composition 6 mm / 16 mm / 6 mm – HD Colours coating on surface #2, ClimaGuard Premium 2S coating on surface #3
Glass 1 & Coating Guardian HD Green on Clear
Glass 2 & Coating Premium 2S
Gap 1 100% Air
Calculation Standard NFRC 2010

TRANSMITTANCE Visible
Ultraviolet 33
Solar Energy 32
Light to Solar Gain (LSG) 0.71
REFLECTANCE Visible Light Outside 27
Visible Light Inside 16
Solar Energy Outside 15
U-VALUE Summer Daytime – Air [W/m²·K] 4.8
HEAT GAIN Relative Heat Gain (RHG) W/m² 383
Solar Heat Gain Coefficient (SHGC) 0.47
COMPOSITION Composition 6 mm – coating on surface #2
Glass 1 & Coating Guardian HD Green on Clear
Calculation Standard NFRC 2010
Gray color & finish
11% light transmission, 24% from the solar factor
THICKNESS TITLE
3 – 12 mm
APPLICATIONS TITLE Facades
Windows
Doors
Curtain Walls
Roofs
Skylights
OPTIONS TITLE Tempered
Laminated
Heat Soaked
Heat Strengthened
AVAILABLE SIZESMaximum Height x Width: 3210 x 6000 mm
RECOMMENDED COATING POSITIONS Monolithic: 2
Double Glazed: 2
EDGE DELETION Required: NO
APPLICATION TYPE Can be used in: Monolithic or Insulating Glass Unit

TRANSMITTANCE Visible Light 30
Ultraviolet 26
Solar Energy 21
Light to Solar Gain (LSG) 1.04
REFLECTANCE Visible Light Outside 28
Visible Light Inside 19
Solar Energy Outside 18
U-VALUE Summer Daytime – Air [W/m²·K] 1.38
HEAT GAINRelative Heat Gain (RHG) W/m² 215
Solar Heat Gain Coefficient (SHGC) 0.28
COMPOSITION Composition 6 mm / 16 mm / 6 mm – HD Colours coating on surface #2, ClimaGuard Premium 2S coating on surface #3
Glass 1 & Coating Guardian HD Green on Clear
Glass 2 & Coating Premium 2S
Gap 1 100% Air
Calculation Standard NFRC 2010

TRANSMITTANCE Visible
Ultraviolet 33
Solar Energy 32
Light to Solar Gain (LSG) 0.71
REFLECTANCE Visible Light Outside 27
Visible Light Inside 16
Solar Energy Outside 15
U-VALUE Summer Daytime – Air [W/m²·K] 4.8
HEAT GAIN Relative Heat Gain (RHG) W/m² 383
Solar Heat Gain Coefficient (SHGC) 0.47
COMPOSITION Composition 6 mm – coating on surface #2
Glass 1 & Coating Guardian HD Green on Clear
Calculation Standard NFRC 2010
Blue color & finish
12% light transmission, 24% from the solar factor
THICKNESS TITLE
3 – 12 mm
APPLICATIONS TITLE Facades
Windows
Doors
Curtain Walls
Roofs
Skylights
OPTIONS TITLE Tempered
Laminated
Heat Soaked
Heat Strengthened
AVAILABLE SIZESMaximum Height x Width: 3210 x 6000 mm
RECOMMENDED COATING POSITIONS Monolithic: 2
Double Glazed: 2
EDGE DELETION Required: NO
APPLICATION TYPE Can be used in: Monolithic or Insulating Glass Unit

TRANSMITTANCE Visible Light 30
Ultraviolet 26
Solar Energy 21
Light to Solar Gain (LSG) 1.04
REFLECTANCE Visible Light Outside 28
Visible Light Inside 19
Solar Energy Outside 18
U-VALUE Summer Daytime – Air [W/m²·K] 1.38
HEAT GAINRelative Heat Gain (RHG) W/m² 215
Solar Heat Gain Coefficient (SHGC) 0.28
COMPOSITION Composition 6 mm / 16 mm / 6 mm – HD Colours coating on surface #2, ClimaGuard Premium 2S coating on surface #3
Glass 1 & Coating Guardian HD Green on Clear
Glass 2 & Coating Premium 2S
Gap 1 100% Air
Calculation Standard NFRC 2010

TRANSMITTANCE Visible
Ultraviolet 33
Solar Energy 32
Light to Solar Gain (LSG) 0.71
REFLECTANCE Visible Light Outside 27
Visible Light Inside 16
Solar Energy Outside 15
U-VALUE Summer Daytime – Air [W/m²·K] 4.8
HEAT GAIN Relative Heat Gain (RHG) W/m² 383
Solar Heat Gain Coefficient (SHGC) 0.47
COMPOSITION Composition 6 mm – coating on surface #2
Glass 1 & Coating Guardian HD Green on Clear
Calculation Standard NFRC 2010
Our Latest Projects
Color disclaimer
The colors shown are intended to represent the actual color. The color is a result of light and reflection, and cannot be accurately photographed online. Actual glass samples should be used for color determination. Please request a sample and discuss colors with the sales department to make sure you are satisfied with the right choice before ordering glass for your project